Product Detail
Product Overview
The breast disease treatment device integrates three mechanisms of action—microcomputer simulation control, infrared photothermal radiation, electrical pulse stimulation, and drug iontophoresis—based on traditional Chinese medicine meridian therapy and other traditional and modern treatment methods, allowing them to interact and treat simultaneously.
Technical Principles
1. Electrical pulse stimulation: Simulates acupuncture effects through intelligent bio-waves of different frequencies, regulating neuromuscular excitability to achieve analgesia and endocrine regulation.
2. Infrared light irradiation: Utilizes near-infrared light with wavelengths of 0.8-3μm to penetrate 4cm of tissue, promoting local microcirculation and cell metabolism, effectively eliminating breast tissue congestion.
3. Magnetic therapy: Adjusts cell polarity through magnetic induction intensity, reducing the concentration of inflammatory factors to achieve anti-swelling and analgesic effects.
4. Drug delivery: Employs ion current-driven targeted drug penetration, increasing drug concentration in the lesion area by 5-8 times.
Applicable diseases
Suitable for the comprehensive treatment of mastitis and breast hyperplasia using electrical stimulation massage, infrared heat radiation, and drug iontophoresis.
Main parameters
1. 10.1-inch color touchscreen with seven different treatment modes to choose from; four independent output channels allow simultaneous treatment of both breasts of two patients.
2. Multiple treatment probes (twenty in total): Offers a variety of probes to choose from based on the patient's condition and the size of the affected area.
3. Features voice, treatment reminder, and music functions. The treatment reminder function allows users to turn off reminders, set 3-minute or 5-minute timers by clicking the "+" or "-" buttons.
4. Infrared radiation intensity is adjustable from level 1 to 18, with increments of 1. When the infrared radiation intensity is set to the highest level (level 18), the probe surface temperature should be ≤60℃ within 30 minutes. The effective spectral wavelength range of the probe is 0.8μm to 3μm.
5. Electrical pulse therapy intensity is selectable from 0 to 99 levels; treatment time is adjustable from 0 to 99 minutes.
6. Electrical pulse output voltage amplitude: The peak output voltage during open-circuit measurement of the device does not exceed 500V.
7. Electrical pulse output current amplitude: Under a load resistance of 500Ω, the output current must not exceed the following limits: 80mA (r.m.s) for frequencies ≤1500Hz, and 100mA (r.m.s) for frequencies >1500Hz.
8. Deluxe integrated trolley-type therapeutic device for easy portability.